A treatment pump and a lotion pump can share the same bottle neck and look almost alike on a shelf, yet they are specified for very different jobs. The treatment pump moves a small, controlled dose — in our current range 0.25 cc or 0.35 cc per stroke — and is chosen for face cream, essential oil and other small-dose treatments rather than for body lotion.
Once the dose is settled, the next question buyers ask is where the return spring sits. The answer changes what the metal is exposed to, which matters more for a cream or serum than for a high-dose lotion.
What a treatment pump is in this range
Our treatment pump range currently lists 37 models, split between 22 with the spring outside the product path and 15 with the spring inside the pump body. All are PP and cover neck finishes from 18/410 up to 28/410, including 18/415, 20/410, 20/415 and 24/410.
The published dose is:
- 0.25 cc per stroke, ±0.025 cc — the majority of the range;
- 0.35 cc per stroke, ±0.035 cc — one model, NB 301-L.
Both figures are a 10% band around the nominal dose. That band is what a filling line has to work with when it checks dose consistency at the start, middle and end of a run.
Inside spring: the spring sits in the product path
In an inside-spring treatment pump the return spring sits inside the pump body, in the path the formula travels. Every stroke pulls product past the spring, and what stays in the pump body between uses stays in contact with it.
That has two practical consequences for a buyer:
- Changeover needs a defined procedure. When the same pump type is used across several formulas, the flushing routine between runs has to be written down and followed, not left to the operator.
- Spring condition belongs in the ageing test. Accelerated ageing should look at the spring surface as well as at the plastic parts — discolouration, pitting or a change in return force are the things to record.
Inside-spring models in the current range include NB 301-N (18/410, 18/415, 20/410, 20/415, 0.25 cc/t ±0.025 cc) and NB 302-J (20/410 and 24/410, 0.25 cc/t ±0.025 cc). Browse the full inside-spring treatment pump selection for the other neck finishes.
Outside spring: the metal stays out of the formula
An outside-spring treatment pump places the return spring outside the main product pathway — below the stem, around the actuator, away from the product itself. The formula travels from the dip tube through the pump body to the actuator without passing over the spring.
This is the arrangement’s real advantage, and it is worth stating plainly:
- The formula does not reach the spring, so the spring cannot be attacked by the product and cannot shed corrosion products into it.
- That lowers the corrosion risk inside the pack and makes the format easier to justify for actives or oil-based formulas where a reactive ingredient would otherwise sit against metal.
- It is the safer default for aggressive or unfamiliar formulations, because the number of metal-to-formula contact points is reduced before testing even starts.
Outside-spring models in the current range include NB 302-A, available in 18/410, 20/410 and 24/410 at 0.25 cc/t ±0.025 cc. See the full outside-spring treatment pump range for other neck sizes.
Side by side
| Selection point | Inside spring | Outside spring |
|---|---|---|
| Spring location | Inside the pump body, in the product path | Outside the main product pathway |
| Formula contact with the spring | Yes — product passes the spring on every stroke | No — the formula does not reach the spring |
| Corrosion exposure | Present; needs a flushing routine and spring inspection in ageing | Reduced to the remaining wetted parts |
| Best fit for | Established formulas already tested in this format | Reactive actives, oils, new formulas still being qualified |
| Published dose | 0.25 cc/t ±0.025 cc; one model 0.35 cc/t ±0.035 cc | 0.25 cc/t ±0.025 cc |
| Neck finishes in the range | 18/410 to 28/410 | 18/410 to 24/410 |
| Models in this range | 15 | 22 |
The comparison describes arrangement, not a ranking of quality. Both types are made from PP and both are tested against the formula they are sold with.

Neck finish comes before anything else
A treatment pump marked 20/410 will not fit a 24/410 bottle because the actuator looks the same. In a code such as 20/410, 20 is the nominal neck diameter in millimetres and 410 is the thread family. Match pump and bottle on the full code, then confirm closure torque, gasket compression and the fit of the pump housing through the bottle opening.
The bottle neck finish guide explains how to read these codes, including the 18 mm and 20 mm sizes used most often on treatment packaging.
What to test before committing
Whichever spring arrangement you choose, the finished pack still has to pass a compatibility test with the real bulk formula. Record:
- dose at first stroke, mid-pack and near-empty, against the ±10% band;
- return force and full stroke recovery after ageing;
- swelling, stress cracking or softening of plastic and elastomer parts;
- spring surface condition, for inside-spring models;
- clogging or stringing with a viscous cream;
- leakage after transport simulation and temperature cycling;
- odour or color change in the formula.
How to choose
Choose outside spring when the formula is new, contains reactive actives, or is oil-based, and you want the metal out of the product path from the start.
Choose inside spring when the formula is already proven in this format, the neck finish you need only exists in an inside-spring model, or the project requires a specific actuator and lock design that the outside-spring range does not offer.
In both cases, start from the neck finish and the dose, then confirm the arrangement against the formula — not the other way round.
What to send with an inquiry
To shortlist a treatment pump, send us:
- bottle neck finish;
- formula type and approximate viscosity;
- target dose per stroke;
- preferred spring arrangement, if already specified;
- lock and actuator preference;
- dip-tube length or bottle drawing;
- color and decoration requirements;
- destination market and estimated quantity.
Minimum order quantity is 10,000 pcs. Free samples are available for treatment pumps, and we can provide material and wetted-parts information for the exact model you shortlist.
Next step: browse the treatment pump range or send your bottle neck finish and target dose and we will shortlist models for sample testing.

